AXONE: ELECTRICAL ERRORS
Right coil P0352 - shorted to positive / open circuit, shorted to negative.
Error cause
•
If shorted to positive: excessive voltage has been detected at PIN 10 of the (BROWN) con-
nector.
•
If the circuit is open, shorted to negative: voltage equal to zero has been detected at PIN 10
of the (BROWN) connector.
Troubleshooting
•
If shorted to positive: disconnect the coil connector, set the key to ON, activate the coil with
Axone and check voltage at connector PIN 2: if there is voltage, restore the cable harness;
if voltage = 0, replace the coil.
•
If the circuit is open, shorted to negative: check the coil connector and the Marelli control
unit connector. If they are not OK, restore; if everything is OK, check cable continuity be-
tween PIN 2 of the coil connector and PIN 10 of the BROWN connector. If there is not
continuity, restore the cable harness; if there is cable continuity, with the key set to KEY ON,
check the cable ground insulation (from coil connector or control unit connector). If this is
not OK, restore the cable harness.
Engine oil pressure sensor
Function:Indicates the instrument panel if there is
enough oil pressure (0.35 +/- 0.15 bar) (5.1 +/-
2.18 PSI) in the engine.
Operation / Operating principle: normally closed
switch. With oil pressure above 0.35 +/-0.15 bar
(5.1 +/- 2.18 PSI), open circuit.
Level in wiring diagram:fuel reserve and oil pres-
sure.
Location:
•
Sensor: in between the engine "V", a
little to the left, under the generator
•
Connector: on the sensor.
Pin-out: Voltage 12V
Instrument panel
Oil sensor failure DSB 07
Error cause
Electrical system GRISO 8V - 1200
ELE SYS - 70