Air temperature sensor
Function
It tells the control unit the intake air temperature in
order to calculate oxygen presence so as to opti-
mise the petrol quantity necessary for correct com-
bustion.
Operation / Operating principle
NTC type sensor (resistance sensor, inversely
variable with temperature).
Level in wiring diagram:Temperature sensors
Location:
sensor: on the right side of the filter
casing, next to the control unit
connector: on the sensor
Electrical characteristics:
Resistance at 0°: 9.75 kΩ ± 5%
Resistance at 10°: 5.970 kΩ ± 5%
Resistance at 20°: 3.747 kΩ ± 5%
Resistance at 25°: 3.000 kΩ ± 5%
Resistance at 30°: 2.417 kΩ ± 5%
Pin-out:
Grey (cable harness side): Ground connection
Pink/black (cable harness side): 0-5 V signal
AXONE:PARAMETERS
Air temperature
In case of failure, the value set by the control unit is 20 °C (68 °F)
AXONE: ELECTRICAL ERRORS
air temperature sensor open circuit, shorted to positive / shorted to negative.
Error cause
If the circuit is open, shorted to positive: excessive voltage has been detected at PIN 18 of
the control unit connector.
If shorted to negative: voltage equal to zero has been detected at PIN 18 of the control unit
connector
Troubleshooting
If the circuit is open, shorted to positive: check sensor connector and Marelli control unit
connector; if not OK, restore cable harness; if OK, check sensor continuity; if it is not OK,
replace the sensor; if it is OK, check the continuity between PIN 18 of the control unit con-